Q1-46 Series Dual Power Automatic Transfer Switch

Product Description

product detail

Control device: built in controller

Product structure: smal volume, nigh current, simpie structure, ATS integration

Features: tast switching speed, low failure rate, convenient maintenance and reliable performance

Wring mode: frort plate wiring Conversion mode power grd to power gnd power gnd to gererator, automabc switching and self recovery

Product frame: 100, 160, 250, 400, 630 Praduct current: 10, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125, 160, 160, 200, 225, 20,315,350 400 500 630A

Product dassifcation: load switch type Pale No: 4 Optional. fire fighting function, power generation function, multi group auxiliary

Standard: GB/T14048.11-2016

ATSE: PC dless

Summary

Automatic transfer switch (ATSE) is set the switches and control logic integrated without additional controller, achieve integration of automatic electromechanical switch. It has functions such as voltage detection, electrical and mechanical interlocking, and can achieve automatic and emergency manual control.

This is the logical control panel from various logical order to manage the machines, operate with the gearbox to achieve, switching spring motor storage, instantaneous release of the acceleration, rapid access to sub-circuit or circuits conversion, it is obvious by the state security confinerment, greatly irmproved the performance of various electrical and mechanical properties :The switches overall de sign with compact solid.

The shell switching components used fiberglass unsaturated polyester resin manufacturing, with a strong dielectric properties, protection and reliability of the operational safety.

Switch power supply system applicable to changeover the main power supply and backup power supply automatically or two sets load equipment and safety isolation automatically.

Switch appearance is beautiful, creative, simple, small size, the entire function is an ideal choice in different occa sions.

Application

Q1 series dual power automatic transfer switch is mainly applicable to the AC 50Hz, rated voltage AC400v, working voltage 220V, rated current 16A to 630A distribution or generator network.

There is a primary and standby power, or as the utlity to generator in loading changeover. At the meanwhile, it can be used for isolation of infre quently connecting and breaking circuits and lines. * This products are widely used in hospitals, banks, high-rise architecture and so on, which are very important place disallow the failure to supply, distribution and automation system.

Performance and characteristics

Adopt the double rowtype composite contact, side pull institutions, micro motor prestore and microelectronicsl control technology, come true zero flashover(no arcing chamber). *

Reliable electrical and mechanical interfocking chain, the implement of the components independently with isolation switch, the use of safe and reliable. *

Using over zero technology, the state of emergency can be enforced under the zero(cut down the 2 ways in the meanwhile) to meet the needs of fire fighting. Executive load isolation switch using a single motor-driven, transfer reliable smooth, no noise, little impact. *

Operators drive only in the implementation of the electrical load isolation by switching transient current, steadyl work without providing current, energy-saving significantly. *

Executive load isolation switch with a mechanical device used to ensure that reliable standby power of non-interference in each other. *

Obvious on-off position indication, padlocks and other functions, high reliability and service life of more than 8000 times Mechatronics design, switching conversion accurate, flexible, smooth and adopt intemational advanced logic control technology, anti-interference capability, without external interference *

Cooperation with the main power on and standby power off, or the main power off and standby on, the main power and standby power are both off, three kinds stability working(I-O-II). *

Easy installation, the control circuit return way adopt the connect and insert terminal connector. *

Four operator models: emergency manual operation, electric remote control operation, emergency disconnected operation under the automatic stating, automatic control operations

Switch structure description

1. The button is in manual and automatic state: control swtch nternal control Ine power suppk. When the button is r automatic mode the swtch can realize automatic conversion and fire fighting double spit When the button is in manual mode and the lock is dosed, the switch can only be operated manually 
2 Oneratina hande: when usina the oneratinn handie tor manual oneraton the hutton must he nre ssed to manua 
3. Indicator indicates the three states (L o, I of the swtch. "T indicates that switch 1 is on. "Il" means switch Il is on "0" indicates that switch I and switch II are all disconnected

Switch control type and corresponding function (indicate the function when ordering)

1. Type I fully automatic 
2. Type I: fully automatic, fire-fighting double spit, can be selected with generator function. 
3. Type I phase loss detection and protection, full-automatic, fire-fighting double split, with generator function 
4. Full automatic: automatic switch and automatic recovery Vhen the common power supply is cut off, the swwitchl will automatically switch to the standby power supply, when the common power supply returns to normal, the switchl wl atomatically return to swtch to the common nower sunolyil 
5. Fire-fighting double split in case of emergency or equipment maintenance, start the self-locking button of 24V firel power supply, switch to "0" position automatically and cut off the dual poer supply

6. When the swtch is switched to "0" position, the passive feedback sional is qutput 
7. With generator (oil engine): when the mains power is cut off (or the phase is broken), it will send the oil engine start signal to make the oil engine start automatically. After the power generation is normal, the switch vill automaticallyl switch to the power generation powwer supply. When the mains power supply returns to normal, the switch will auto -matically return to the mains power supply and send the oil engine shutdown signal to automatically shut down the oil engine.

Switch debugging instructions

1. Use the operating handle and operate the switch three times repe atedly. The switch should be operated flexibly.
 2. Fully automatic debugging connect the corresponding line according to the wiring diagram, turn on the button switch after confirming that there is no error, and then turn on the double power supply, and the switch should bel turned to I", then disconnect the common powwer supply, the switch should be turned to the "ll" position, and then turn on the common power supply the switch should return to the "I" position. 
3. Fire-fighting debugging in any state, start 24V fire power supply, the switch should be tuned to the "0" positionl 
4. Detection signal indicator: when the common/standby powwer supply is onioff, when the switch "I/tl is on or off,leach signal indicator shall give corresponding indication 
5. After debugging, please turn of the power supply first, and then tum the switch to "D position with the handle.

Message

Related products

Q1-100E Series Dual Power Automatic Transfer Switch

Q1-100E Series Dual Power Automatic Transfer Switch

Click to Learn More

Q1-48 Series Dual Power Automatic Transfer Switch

Q1-48 Series Dual Power Automatic Transfer Switch

Click to Learn More

HGLD Series Dual Power Automatic Transfer Switch

HGLD Series Dual Power Automatic Transfer Switch

Click to Learn More

Related News

> Relay Supplier Introduction

Relay is an electrical control device. When the change of input quantity (such as voltage, current, temperature, etc.) reaches the specified requirements, it can mak...

> Working Principle of Dacheng relay

A relay controls the operation of large currents through small currents, and plays the role of automatic adjustment, safety protection, and circuit conversion.